Specifications
Electrical parameters
| Light source | LED |
| Supply voltage | AC 220–240 V / 50–60 Hz |
| Connection | Pre-wired cable, pre-wired cable with connector (G) |
| Control gear | Electronic driver with surge protection (L/N–PE 10 kV) |
| Surge protection | Additional surge protection 10 kV (S) |
| Control options | No control (1), DALI (4), night dimming (A) |
| Constant lumen output | CLO (C) |
Light parameters
| Optical system | Roads (Mxx), roads (Lxx), directional (Pxx) Area (Uxx), combined (Kxx) AMBER module (Nxx), AMBER optics (ALxx), BACK light mask (BM2) |
| Light distribution | Direct |
| Colour rendering index | CRI > 70, CRI > 80 |
| Colour temperature | BLUE FREE™ (AMBER) / 2,200 K / 2,700 K / 3,000 K / 4,000 K / 5,000 K |
| Lifetime | > 100,000 h (L90B10) |
Construction
| Luminaire housing | Cast aluminium |
| Colour | RAL 7015; other RAL (on request) |
| Surface type | Matt |
| Surface finish | Toughened glass |
Safety
| Protection class | I, II |
| Maximum ambient temperature | −40/+55 °C |
| Ingress protection | IP66 |
| Impact resistance | IK09 |
Mounting
| Mounting method | Pole mounted (48–60 mm) |
| Recommended height | Up to 6 m |
| Mounting height | Sidewalks, class S roads, urban parks, squares, parking areas |