Specifications

Electrical parameters

Light source LED
Power voltage AC 220–240 V / 50–60 Hz
Connection method leading out cable, leading out cable with connector (G)
Ballast part electronic driver with surge protection L/N-Ground 10 kV
Surge protection additional surge protection 10 kV (S)
Fuse fuse 6,3 A (J)
Possibility of regulation non-dimmable (not labeled), DALI (max. 3 care cable), night dimming (A)
preparation for wireless communication NEMA (N), Zhaga (Z)
Constant lumen output CLO (C)

Light parameters

Optical system roads (Mxx), roads (Lxx), directional (Pxx)
area (Uxx), AMBER modul (Nxx), AMBER optics (ALxx)
combined optics (Kxx), BACK Light mask (BM2)
Light distribution direct
Colour rendering index Ra > 70, Ra > 80
Colour temperature AMBER / 2,200 K / 2,700 K / 3,000 K / 4,000 K / 5,000 K / TW
Service life > 120 000 hrs. (L90)

Construction

Luminaire body aluminum cast
Colour RAL 7015/9006, other RAL (on request)
Surface type matte
Luminaire cover tempered glass

Safety

Protection class I, II
Maximum ambient temperature -40 / 55 °C
Ingress protection IP 66
Impact protection     IK 09 
EMC YES
Vibration test YES
Static load test YES
Corrosion test – Salty spray YES (1500 hours)
Lifetime test YES
Certification ENEC+, ENEC, Zhaga-D4i , IDA Dark Sky ApprovedMounting
CB mark YES
RoHS YES
REACH YES

 

Method pole or boom mounted (48–60 mm)
Recommended height max. up to 12 m
Use bike path, outdoor areas, pedestrian zones, square, sidewalks

 

* Can not be produced under ENEC licence
** Weight may vary depending on the luminaire variant
Luminaire ambient temperature TQ 25 °C
Initial color consistency: ≤ 5 SDCM
IDA fixture seal of approval relates to ≤ 3 000 K
To meet IDA requirements, the luminaires must be installed horizontally with the road
Optical and electrical parameters tolerance ± 10 %

When using the CLO function, the initial power and luminous fluxis 10 % lower than the value shown in the table.
LDT curves with CLO function have the letter “C” at the end of their marking.